Product specifications
Server Failover Requirements
18
Server Failover Requirements
You should make sure the server failover system meets the following requirements.
Hardware
The automatic server failover system was qualified with the following hardware:
• Two Avid AS3000 servers functioning as nodes in a failover cluster. For installation
information, see the Avid AS3000 Setup Guide.
• Two ATTO Celerity FC-81EN Fibre Channel host adapters (one for each server in the
cluster), installed in the top PCIe slot.
• One of the following
- One Infortrend
®
S12F-R1440 storage array. For more information, see the Infortrend
EonStor
®
DS S12F-R1440 Installation and Hardware Reference Manual.
-One HP
®
MSA 2040 storage array. For more information, see the HP MSA 2040 User
Guide and other HP MSA documentation.
c
The Infortrend A16F-R2431 (Gen 2) is not supported for use with the FC-81EN host
adapter.
The servers in a cluster are connected using one or more cluster shared-storage buses and one or
more physically independent networks acting as a heartbeat.
Server Software
The automatic failover system was qualified on the following operating system:
• Windows Server 2008 R2 Enterprise
A license for the Interplay Engine failover cluster is required. A license for a failover cluster
includes two hardware IDs. For installation information, see
“Installing a Permanent License” on
page 109
.
Space Requirements
The default disk configuration for the Infortrend shared RAID array is as follows:
Disk
Infortrend
S12F-R1440
Disk 1 Quorum disk 10 GB
Disk 2 (not used) 10 GB