0040-17001-01 (Revision W) Installation Page 2-23
2.3.8.1 Installation
CAUTIONS
1. Do not press or contact the display surface of the unit when inserting into
the Rack.
2. Panel Retainer torque limit is 5.0 inch-pounds.
3. Prior to inserting the NGT-9000 into the rack, sight down the inside of
the mounting tray to assure that the RF-connectors (A-1 thru A-5) are
aligned facing straight toward the tray opening. If these connectors are
angled, damage to the connectors or the NGT-9000 may result.
1. When installing the panel rack make sure that it is installed flush or slightly forward of the
instrument panel as shown in Figure 2-14.
2. Before inserting the NGT-9000 into the Panel Rack, rotate the Panel Retainer screw CCW using a 3/32
Hex Head Driver until it stops (fully disengaged).
3. Insert the NGT-9000 in Panel Rack allowing the alignment guides to settle the unit into place. Do
not press or contact the display surface of the unit when inserting into the Rack.
4. Rotate the Panel Retainer CW (approximately 40 turns) to lock the unit in place. The Panel Retainer
torque limit is 5.0 inch-pounds.
5. Observe that a small gap is showing between the NGT-9000 bezel and the A/C Instrument panel.
Contact between the NGT-9000 bezel and the A/C Instrument panel may prevent the unit from fully
seating in the Panel Rack.
Figure 2-14: Panel Installation