Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Installation Page 2-9
2.3.4 Compatible Equipment Installation Information
Use the information in this section for installing compatible equipment. Additional information may be
found in the General Information section under Equipment Interfaces and Appendix C (Equipment
Compatibility and Diagrams.).
2.3.4.1 PIM-9000
The PIM-9000 WiFi Module is preconfigured by the manufacturer. The PIM-9000 WiFi Module may be
connected to the NGT-9000 circuit breaker through a 1/4 amp in line fuse. Refer to Figure 2-5 for
dimensional information.
Figure 2-5: PIM-9000
2.3.4.2 WX-500
Release 2.1 or greater. The WX-500 Weather Mapping System (lightning detection) has multiple
installation options available as defined below. The WX-500 interface is not available on the Remote
Mount version NGT-9000R.
WX-500 transmits data to the NGT-9000 via RS-232 #1 or RS-422 #1. Configured using the MPC
(MAT).
WX-500 receives heading from RS-232 #1 from the NGT-9000 (which receives heading via ARINC
429) or the WX-500 has heading input from a Synchro system and outputs that heading information
to the NGT-9000 via RS-232 #1 or RS-422 #1.
Use the MPC (MAT) to review configuration information and Fault data. Refer to the installation
checkout section (3.9.5) for details.
Noise Monitor, Test Strikes, and Self-Test procedures for testing and troubleshooting an installation
are available in the Maintenance section (para 4.4.5) of this manual. Additional information is
provided in the WX-500 Installation Manual.