Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) General Information Page 1-25
Table 1-7: Specifications for Detachable Configuration Module
PART NUMBER:
9230-17003-01
CERTIFICATION:
USA (FAA): TSO-C145c, C154c, C157a, C195a.
See paragraph 1.7 for specific TSO information.
Listed are current authorizations at time of publication, contact Field
Service Engineering for latest certification information
RTCA COMPLIANCE:
The DCM is tested as part of the Lynx NGT-9000
WEIGHT:
Negligible
SIZE:
Length: 6 inches (includes wires)
POWER
REQUIREMENTS:
3.3 Vdc (regulated via J1 connector)
INTERFACE (S):
I
2
C serial interface
OPERATING
TEMPERATURE:
-45° to +70°C (-49° to +158°F)
STORAGE
TEMPERATURE:
-55° to +85°C (-67° to +185°F)
MAXIMUM ALTITUDE:
55,000 ft. (installation environment)
SCHEDULED
MAINTENANCE:
None
SERVICE LIFE:
Unlimited
REPAIRABILITY:
Replacement only
1.7 TSO INFORMATION
TSO and Failure Classification Information is located in Appendix D.
1.8 MODIFICATIONS
Modifications (MODS) are identified by an entry on the I.D tag on individual units. A list of
modifications to the Lynx NGT-9000 is identified below:
Table 1-8: Hardware Modifications
MOD # EFFECTIVITY / COMPLIANCE DESCRIPTION
A 9029000-20000 and 9029000-40000
MOD A is Optional for installations
with 14 VDC aircraft power sources.
To inform customers that due to variability in 14
VDC aircraft power sources, Hardware MOD A
may be required to ensure consistent power up
operation. Service Bulletin SB9029000-3.
B 9029000-20000 and 9029000-40000
MOD B is recommended.
To inform customers of a TAS antenna calibration
error causing the bearing calibration performed by
the NGT to become corrupted and fail.
Service Bulletin SB9029000-4.
C 9029000-20000 and 9029000-40000
MOD C is optional.
To update a power amplifier component and
change the label with new FCC identification.
Service Bulletin 8210400-001.