Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) General Information Page 1-21
Table 1-5: Specifications for Panel Mount NGT-9000
OPERATION:
Start Up Time: On Ground 20 seconds or less
In air 5 seconds or less
Display Luminance: Range 0.05 fL to 150 fL
Built In Test: Fault Monitoring on all stages of operation from
start up to power down.
UAT Receiver Sensitivity
(Class A1S)
-95.0dBm for 90% Message Decoding for Long
ADS-B Messages
-96.0dBm for 90% Message Decoding for
Short ADS-B Messages
-93.0dBm for 90% Message Decoding for
Ground Uplink Messages
1090 ADS-B Receiver
Sensitivity (class A2):
-79dBm for 90% message decoding for
1090MHz ADS-B messages
Mode S Transponder Power (Class 1 Transponder). 125W minimum, 250 W
maximum (Part 43 Appendix F: Class 2A)
TAS/TCAS Output Power (Class A TAS) (TCAS I) 125W minimum, 250
W maximum
TAS/TCAS Receiver
Sensitivity
-74.5 dBm +/- 3 dB (referenced at rear
connector)
SCHEDULED
MAINTENANCE:
No scheduled maintenance is required. As a transponder device, FAA
document 91.413 requires testing and inspection of a transponder every 24
months.
SERVICE LIFE:
The Lynx NGT-9000 has unlimited service life.
REPAIRABILITY:
Repairs performed at the FAA certificated Repair Station co-located at the OEM
(equipment) facility.