1.6 SPECIFICATIONS
Table 1-5: Specifications for Panel Mount NGT-9000
PART NUMBERS:
9029000-20000
CERTIFICATION:
Release 1
USA (FAA): TSO-C112d, C113a, C145c, C147, C154c, C157a, C166b, C195a
Release 2
USA (FAA): TSO-C112d, C113a, C145c, C147, C151c, C154c, C157a, C166b,
C195b
Release 3
USA (FAA): TSO-C112d, C113a, C145c, C147, C151c, C154c, C157a, C166b,
C195b, C118a
See paragraph 1.7 for specific TSO information.
Listed are current authorizations at time of publication, contact Field Service
Engineering for latest certification information
ADVISORY
CIRCULARS:
AC20-21-46, AC20-115B, AC20-152, AC20-165B, AC20-172A
RTCA COMPLIANCE:
Environmental Category: DO-160G (See Environmental Qualification Form in
Appendix B.)
Software Category: DO-178B, Design Assurance Level C
Hardware Category: DO-254, Design Assurance Level C
Other: DO-181E, DO-197A, DO-229D, DO-260B, DO-267A, DO-282B, DO-
317A, ARINC 718A-4 and SAE AS8034B.
COMPLIANCE:
ATC transponder functionality: 14 CFR 91.215, 91.217, 91.413
ADS-B Out functionality: 14 CFR 91.225, and 91.227
The Lynx NGT-9000 has been shown to meet the requirements in TSO-C166b
and meets the requirements of 14 CFR 91.225a installed in accordance with
these installation instructions.
FCC:
FCC Identifier 2ACTZMSS90 Hardware MOD B and earlier.
FCC Identifier 2ACTZMSS9019 Hardware MOD C and later.
SIZE:
See the following figures for dimensions:
Figure 2-1: Outline Dimensions for Panel Mount NGT-9000
Figure 2-2: Outline dimensions for Panel Mount Mounting Rack NGT-9000
Note: Unit Fits into a standard MARK width (6.25 in) panel.
WEIGHT:
2.96 Lbs. (1.35 kg)
CHASSIS GROUND:
Bonding impedance between aircraft ground and the Lynx NGT-9000 Chassis
must be less than 2.5 milliohms.
POWER
REQUIREMENTS:
+14.0 VDC nominal. 19.0 watts nominal (24.0 Watts maximum)
+28.0 VDC nominal. 19.0 watts nominal (24.0 Watts maximum)
Note - Due to variability in 14 VDC aircraft power sources, Hardware Mod A may be required to
ensure consistent power up operation.