Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Appendix B Page B-1
Appendix
B
Environmental Qualification Form
B.1 INTRODUCTION
This appendix includes the environmental qualifications form required for the Lynx NGT-9000,
Detachable Configuration Module, NY156, and NY164 Directional Antenna.
B.2 LYNX NGT-9000 ENVIRONMENTAL QUALIFICATION FORM
PRODUCT
DESCRIPTION:
Multilink Surveillance System
Panel Mount
Multilink Surveillance System
Remote Mount
TYPE DESIGNATION: NGT-9000D Release 1, 1.1 (HW)
Release 1, 2, or 3 (SW)
NGT-9000RD Release 1, 1.2 (HW)
Release 1, 2, or 3 (SW)
MODEL: NGT-9000, NGT-9000+,
NGT-9000D, NGT-9000D+
NGT-9000R, NGT-9000R+,
NGT-9000RD,
NGT-9000RD+
HARDWARE PART NO.: 9029000-20000 9029000-40000
MANUFACTURER: Aviation Communication and Surveillance Systems
ADDRESS: ACSS 19810 N. 7th Avenue Phoenix, AZ 85027-4741
PRODUCT DESCRIPTION:: Detachable Configuration Module
PART NUMBERS: 9230-17003-01
MANUFACTURER: Aviation Communication and Surveillance Systems
ADDRESS: ACSS 19810 N. 7th Avenue Phoenix, AZ 85027-4741
DESCRIPTION
SECT.
NO. CAT. DESCRIPTION
Temperature and Altitude
Low Temperature
4.5.1
4.5.2
A1/F1
Panel Mount: -20° C Operating
-40° C Short Time Operating.
-55° C Ground Survival
B2
Remote Mount: -45° C Operating
-45° C Short Time Operating.
-55° C Ground Survival
High Temperature
4.5.3
4.5.4
A1/F1
Panel Mount: +55° C Operating
+70° C Short Time Operating
+85° C Ground Survival
B2
Remote Mount: +70° C Operating
+70° C Short Time Operating
+85° C Ground Survival
In-Flight Loss of
Cooling
4.5.5 X
Not Applicable, Not Tested.
External Cooling Not Required
Altitude 4.6.1 A1/F1 Tested to 55,000 ft. Maximum Operating Altitude
Decompression 4.6.2 A1/F1 8,000 ft. to 55,000 ft.