Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Appendix A Page A-22
PIN 51
Signal Name:
RS422_RXA ( - ) (inverting)
Signal Function:
RS-422 Input # 1
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.6
PIN 52
Signal Name:
RS422_TXB ( + ) (non-inverting)
Signal Function:
RS-422 Output # 1
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.6
PIN 53
Signal Name:
RS422_TXA ( - ) (inverting)
Signal Function:
RS-422 Output # 1
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.6
PIN 54 thru PIN 59
Signal Name:
Spare
Signal Function:
Spare pin
Electrical Characteristics:
---
Connection:
No Connection
Comments: