Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Appendix A Page A-21
PIN 47
Signal Name:
RX4_429B (ARINC 429_4_IN B)
Signal Function:
Configurable - Combo Bus 429 #2
Release 3.2 and later - ARINC 429 4 Input B (Control
Panel 2 Aft or Right)
Electrical Characteristics:
Configuration Option:
Release 3.2 and later: Low Speed ARINC 429 (12.0 to
14.5 kbps) only.
High Speed ARINC 429 (100 kbps). Release 3.1 or
earlier.
Release 3.2 Configuration Option. Used on NGT-
9000R for dual ARINC 429 Control Panel 2.
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.7.
PIN 48
Signal Name:
TX_429A (ARINC 429_OUT A)
Signal Function: ARINC 429 Output for CDTI display
Release 3.2 and later - ARINC 429 Output A (Control
Panel 1)
Electrical Characteristics:
High Speed ARINC 429 (100 kbps)
L-3 Sky-497 STIF format (config option)
Control Panel (Release 3.2 config option) Used on NGT-
9000R for dual ARINC 429 Control Panel.
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.8
PIN 49
Signal Name:
TX_429B (ARINC 429_OUT B)
Signal Function:
ARINC 429 Output for CDTI display
Release 3.2 and later - ARINC 429 Output B (Control
Panel 1)
Electrical Characteristics: High Speed ARINC 429 (100 kbps)
L-3 Sky-497 STIF format (config option)
Control Panel (Release 3.2 config option) Used on NGT-
9000R for dual ARINC 429 Control Panel.
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.8
PIN 50
Signal Name:
RS422_RXB ( + ) (non-inverting)
Signal Function:
RS-422 Input # 1
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments: