Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Appendix A Page A-20
PIN 44
Signal Name: RX3_429A (ARINC 429_3_IN A)
Signal Function:
Reserved
Release 3.2 and later - ARINC 429 3 Input A (Control
Panel 1 -– Front or Left).
Electrical Characteristics:
Configuration Option:
Low Speed ARINC 429 (12.0 to 14.5 kbps)
High Speed ARINC 429 (100 kbps)
Release 3.2 Configuration Option. Used on NGT-
9000R for dual ARINC 429 Control Panel.
Data speed is low
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.7.
PIN 45
Signal Name:
RX3_429B (ARINC 429_3_IN B)
Signal Function: Reserved
Release 3.2 and later - ARINC 429 3 Input B (Control
Panel 1 -– Front or Left).
Electrical Characteristics:
Configuration Option:
Low Speed ARINC 429 (12.0 to 14.5 kbps)
High Speed ARINC 429 (100 kbps)
Release 3.2 Configuration Option. Used on NGT-
9000R for dual ARINC 429 Control Panel.
Data speed is low
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.7.
PIN 46
Signal Name:
RX4_429A (ARINC 429_4_IN A)
Signal Function: Configurable - Combo Bus 429 #2
Release 3.2 and later - ARINC 429 4 Input A (Control
Panel 2 Aft or Right)
Electrical Characteristics: Configuration Option:
Release 3.2 and later: Low Speed ARINC 429 (12.0 to
14.5 kbps) only.
High Speed ARINC 429 (100 kbps). Release 3.1 or
earlier.
Release 3.2 Configuration Option. Used on NGT-
9000R for dual ARINC 429 Control Panel 2.
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.7.