Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Appendix A Page A-8
A.2.11 I
2
C Serial Bus (Detachable Configuration Module)
The I
2
C serial bus is used to communicate with the Detachable Configuration Module to store the
configuration options set up in the Installation Checkout section using the MPC (MAT).
A.2.12 Antenna Connections
The unit has 5 antenna connections labeled A1 thru A5. All models of the Lynx NGT-9000 are required
to have GPS and Omnidirectional (UAT) cable connections (A5 & A3). Models with TAS/TCAS have
three cables connecting to A1, A2, and A4. Models with Diversity only (no TAS/TCAS) have one cable
connecting to A2.