Installation Manual
0040-17001-01 (Revision W) Maintenance Page 4-50
4.7 DISPOSITION OF FAILED ITEMS
1. The Lynx NGT-9000 can only be repaired by a ACSS Certified Repair Station Center.
2. The configuration module, NY156, and NY164 cannot be repaired and must be replaced.
3. Contact ACSS Customer Service to obtain a Return Material Authorization (RMA). Shipping
Instructions will be provided with the RMA.
4. Refer to the manufactures data for external displays, controllers, and antennas interfaced to the Lynx
NGT-9000.
5. If available, pack components in their original shipping container. If the original container is not
available, pack them as follows:
CAUTION
Do not use desiccant crystals when packaging electronic
assemblies. Since the assembly must be packed tightly, crystals in
bag form cannot be used. The use of loose crystals may cause
unnecessary damage resulting in a cleaning problem.
a. Ensure that conductive covers/caps are installed on the exposed terminals of connector, if
applicable.
b. LRU's that are marked as electrostatic discharge sensitive (ESDS) must be wrapped in static
protective materials.
c. Wrap with bubble pack. Secure bubble pack with reinforced tape.
d. Place assembly in a cardboard box.
e. Wrap any accessories in tissue and place in the box. Fill spaces with bubble pack.
f. Place an explanation letter in the box with the following information.
Your name, address, and telephone number
Purchase order number
Description of component including, when applicable, model and serial number
A brief description of the difficulty
g. Shut box, and seal with reinforced tape.
h. Attach packing list to outside of box.