Installation Manual
Table Of Contents
- 17001_0_Frt-Matr
- 17001_1_Gen-Info
- 1.1 INTRODUCTION
- 1.2 FUNCTIONAL DESCRIPTION
- 1.2.1 Software Release Summary
- 1.2.2 Transponder Functional Overview
- 1.2.3 GPS Functional Overview
- 1.2.4 Lightning Detection (optional)
- 1.2.5 ADS-B System Overview
- 1.2.6 Traffic Display Functional Overview
- 1.2.7 FISB System Overview
- 1.2.8 Traffic Awareness System (option) Overview
- 1.2.9 ADS-B Traffic Advisory System Overview (optional)
- 1.2.10 Traffic Alert and Collision Avoidance System (option) Overview
- 1.2.11 Terrain Awareness and Warning System Overview (optional)
- 1.2.12 TerrainVisionTM
- 1.2.13 Discrete Inputs and Outputs Functional Overview
- 1.3 EQUIPMENT DESCRIPTIONS
- 1.4 INTERFACES
- 1.4.1 ADS-B Out Fail
- 1.4.2 AHRS Input
- 1.4.3 Altitude Encoder Input
- 1.4.4 Audio Out
- 1.4.5 Standby Mode
- 1.4.6 Audio Mute In and Out
- 1.4.7 Audio Acknowledge
- 1.4.8 RF Suppression Input/output
- 1.4.9 Traffic Alert
- 1.4.10 TAWS Caution and Warning Alert
- 1.4.11 WiFi Interface
- 1.4.12 WOW Input
- 1.4.13 Maintenance Interface
- 1.4.14 GPS Antenna
- 1.4.15 L-Band (978/1030/1090 MHz) Antenna
- 1.4.16 Directional Antenna
- 1.4.17 Traffic Display
- 1.4.18 Weather Display
- 1.4.19 Lightning Detection (WX-500)
- 1.4.20 Control Panel
- 1.5 INSTALLATION CONSIDERATIONS
- 1.6 SPECIFICATIONS
- 1.7 TSO INFORMATION
- 1.8 MODIFICATIONS
- 1.9 SOFTWARE REVISIONS
- 1.10 EQUIPMENT REQUIRED NOT SUPPLIED
- 1.11 EQUIPMENT INTERFACES
- 1.12 OBTAINING SOFTWARE
- 1.13 INSTALLATION PROCEDURE FOR LYNXMSS USB DRIVER
- 1.14 INSTALLATION APPROVAL AND LIMITATIONS
- 17001_2_Instal
- 2.1 INTRODUCTION
- 2.2 UNPACKING AND INSPECTING
- 2.3 INSTALLATION PROCEDURES
- 2.3.1 Panel Mount Location
- 2.3.2 Remote Mount Location
- 2.3.3 Electrical Connections
- 2.3.4 Compatible Equipment Installation Information
- 2.3.5 Discrete Inputs and Output Connections
- 2.3.6 Installation Guidelines for the DCM
- 2.3.7 P1 Mating Connector Assembly
- 2.3.8 Panel mount NGT-9000 Installation
- 2.3.9 Remote Mounted Lynx NGT-9000 Installation
- 2.3.10 CP-2500 Installation Guidelines
- 2.3.11 Antenna Installation Guidelines
- 17001_3_Inst_Check
- 3.1 INTRODUCTION
- 3.2 BASIC OPERATION
- 3.3 MPC (MAT) OPERATION
- 3.4 INSTALLATION PROCEDURE FOR LYNXMSS USB DRIVER
- 3.5 MAINTENANCE MODE
- 3.6 VERIFY SOFTWARE VERSION
- 3.7 SELECT CONFIGURATION OPTIONS
- 3.8 CALIBRATION SETUP
- 3.9 INTERFACE CHECK
- 3.10 SETUP PIM-9000 WIFI MODULE
- 3.11 INSTALLATION CHECKOUT
- 3.11.1 Functional Checks
- 3.11.2 Ground Checks
- 3.11.3 Electromagnetic Interference (E.M.I.) Check
- 3.11.4 Panel mount NGT-9000 Display Check
- 3.11.5 Flight Test
- 3.11.6 Installation Checkout Complete
- 17001_4_Maint
- 17001_5_App-A_signal
- A.1 INTRODUCTION
- A.2 INPUT AND OUTPUT INTERFACES
- A.2.1 Input Power
- A.2.2 RF Suppression Bus
- A.2.3 Audio Output
- A.2.4 Gillham Input (Altitude Input)
- A.2.5 RS-232 Interface
- A.2.6 RS-422 Interface
- A.2.7 ARINC 429 Input
- A.2.8 ARINC 429 Output
- A.2.9 Discrete Input
- A.2.10 Discrete Output
- A.2.11 I2C Serial Bus (Detachable Configuration Module)
- A.2.12 Antenna Connections
- A.3 PIN DEFINITION SUMMARY
- A.4 [J1 CONNECTOR]
- 17001_6_App-B_Environmental
- 17001_7_App-C_Compatibility
- 17001_8_App-D_TSO
- 17001_9_App-E_Questionaire
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Maintenance Page 4-48
4.6.4 Detachable Configuration Module
Use this procedure to remove and replace the DCM. The instructions herein are generic in scope. The best
established methods, techniques and practices should be used where no specific procedure is given.
NOTE
Before removal (and if possible) the configuration data should be saved.
Refer to the MPC (MAT) Backup instructions located in the installation
checkout section.
1. Removal Procedure
a. Locate the Panel Retainer access on the bottom left of the Lynx NGT-9000 bezel.
b. Rotate the Panel Retainer CCW using 3/32 Allen Hex Socket Screw Driver.
c. Pull the unit from panel separating the main connector and antenna connections.
d. Remove 6 screws securing panel rack and remove panel.
e. Remove 4 screws securing rear plate to panel rack.
f. Remove 2 screws securing P1 mating connector and nut plate. Remove screw securing ground
strap to rear plate.
g. If installed - Remove tie wraps securing overbraid to the wire bundle.
h. If installed - Slide overbraid to expose configuration module.
i. Remove configuration module contacts from the P1 mating connector.
2. Installation Procedure
a. Insert contacts of new configuration module into P1 mating connector. Refer to Installation
Guidelines for the Configuration Module in the installation section for details on the
configuration module and configuration module electrical interface.
b. If installed - Slide overbraid back into position, and use a new tie wraps to secure overbraid.
c. Secure P1 mating connector to rear plate using nut plate and 2 screws.
d. Secure cable ground strap to rear plate using 1 screw.
e. Secure rear plate to panel rack using 4 screws.
f. Insert panel in installation location and secure panel using 6 screws.
g. Secure panel rack using 6 screws.
h. On the Lynx NGT-9000 use 3/32 Allen Hex Socket Screw Driver to rotate the panel retainer
counterclockwise to avoid interference with the bottom edge of the panel.
i. Insert the Lynx NGT-9000 in panel allowing the alignment guides to settle the unit into place.
j. Press the sides of the unit until the back side of the bezel is against the panel.
k. Rotate the panel retainer clockwise to lock the Lynx NGT-9000 in place. The Panel Retainer
torque limit is 5.0 inch-pounds.
3. Functional Check Procedure
a. Cycle power to the Lynx NGT-9000 and system components.
b. Ensure no failure messages are annunciated on the controller/display/PED and fail lamp is
extinguished after GPS has acquired a signal.
c. Use the installation checkout section to perform the select configuration options procedure or
use the maintenance sections configuration restore is the original configuration (.bin) file can be
retrieved from the original installer of the configuration module.
d. Perform the checkout procedure provided in the installation checkout to verify unit is
functioning correctly.
• Refer to the fault isolation section if errors are detected.