0040-17001-01 (Revision W) Maintenance Page 4-46
4.5.5 Service
This procedure is used to service and troubleshoot the Lynx NGT-9000. See Figure 4-12.
4.5.5.1 Data Recording
The information generated by the Data Recording page is not typically used unless requested by the
factory during service.
1. From the MPC (MAT) select ServiceZData Recording.
2. Select the MMC Mode.
Selecting Truncate restarts the recording.
Selecting Append adds any new recording to the end of the current data recording.
3. Click on the “Enable” button.
4. From the MPC (MAT) select ServiceZRestart UnitZ Operational Mode.
5. Data recording begins. Recording continues until the unit is restarted again.
6. When needed use the ‘Clear’ button’ to erase the current recorded data.
7. The data can be stored to a file using the ‘Browse’ and “Download’ buttons.
4.5.5.2 Live Data
The Live Data function is used for troubleshooting. Instructions on how to use live data are located in the
Installation Checkout section under configuration check.
Figure 4-12: MPC (MAT)Service