Installation Manual
0040-17001-01 (Revision W) Maintenance Page 4-45
4.5.4 Configuration Restore
This procedure is used to automatically fill in the configuration options from a backup file. See Figure
4-11. Perform the following procedure using a MPC and MPC (MAT). This procedure assumes that the
unit is in Maintenance Mode and the MPC is interfaced to the unit using either the USB.
These procedures assume the following:
Power is being supplied to the aircraft and Lynx NGT-9000.
The MPC (MAT) is active on the MPC.
The MPC is connected to the unit.
A DCM is connected (via the mating connector)
The MPC and unit are communicating. If not then from the MPC (MAT) panel, select
ConnectZNGT9000ZUSB. This is required each time the unit power is cycled.
1. From the MPC (MAT) select Setup Z Configuration Z Restore. See Figure 4-11.
2. Click on the Load button to ‘Load a Pre-Existing Configuration File’ to load the configuration data
into the MPC (MAT). After the file is loaded into the MPC (MAT) click on any of the Apply buttons
to save all the configuration options (see Note below). Note - A dialog window is shown asking if
changes should be saved immediately. See instructions given in the Installation Checkout section.
NOTE
The Tail Number and Mode S Identifier are unique for every aircraft. From
the MPC (MAT) select Setup Z Configuration Z Modify Z Aircraft
Specific and enter the new data before pressing the Apply button.
3. Click on the Restore button to Restore Installation Configuration from Backup (NVM) to save the
backup configuration module data stored in the unit’s memory to the configuration module.
4. Click on the Set Defaults button to load default information to the configuration module.
5. From the MPC (MAT) select ServiceZRestart Unit ModeZ Maintenance.
Figure 4-11: MPC (MAT)Configuration Restore