0040-17001-01 (Revision W) Maintenance Page 4-41
Table 4-4: List of Fault Log Messages
FAULT ID/ CODE
(HEX)
FAULT DESCRIPTION CORRECTIVE ACTION
0x00002004
1090 ADSB Rcvr Top Power Failure
ADS-B In Internal degraded
TAS Internal failure
TCAS Internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00002005
TAS/TCAS 1090 (ATCRBS)
Receiver Data Failure
TAS Internal failure
TCAS internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00002008
FPGA TAS/TCAS 1030 transmission
failure
TAS Internal failure
TCAS internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00002009 TAS/TCAS 1030 Transmission
Power Failure
TAS Internal failure
TCAS internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00002801
Clear audio Mute While On Ground
Log the fault.
0x00002802
Clear AS Antenna Failure
Log the fault.
0x00002803
Clear 1090 ADSB Rcvr Btm Power
Failure
Log the fault.
0x00002804
Clear 1090 ADSB Rcvr Top Power
Failure
Log the fault.
0x00002805
Clear TAS/TCAS 1090 (ATCRBS)
Receiver Failure
Log the fault.
0x00002808
Clear FPGA TAS/TCAS 1030
transmission failure
Log the fault.
0x00002809
Clear TAS/TCAS 1030 Transmission
Power Failure
Log the fault.
0x00003001 Invalid Mode S Address
Transponder External failure
ADS-B Out Internal failure
Change DCM setting (ICAO address
should be other than 00000 or FFFFFF
in hex). See installation checkout for
details.
0x00003002 FPGA 1090 Transmission Failure
Transponder Internal failure
ADS-B Out Internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00003003
Squitter rate failure
ADS-B Out Internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00003004
Squitter scheduler process not
running at expected rate
ADS-B Out Internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00003005
1090 ATCRBS Rx Failure(loopback
without TAS antenna)
Transponder Internal failure
ADS-B Out Internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00003006
1030 Rcvr Btm Power Failure
Transponder Internal failure
TAS Internal failure
TCAS Internal failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.