0040-17001-01 (Revision W) Maintenance Page 4-39
Table 4-4: List of Fault Log Messages
FAULT ID/ CODE
(HEX)
FAULT DESCRIPTION CORRECTIVE ACTION
0x0000100D
Map DB Flash CRC Failure
Map database failure
FIS-B internal degraded
Reboot the unit and check if the fault
persists. May need to update or load
map database data.
Contact ACSS Field Service before
removal.
0x0000100E Map DB Flash Compatibility Failure
Map database failure
FIS-B internal degraded
Reboot the unit and check if the fault
persists. May need to update or load
map database data.
Contact ACSS Field Service before
removal.
0x0000100F TAWS Terrain DB Flash Failure
Possible Cause
TAWS Internal failure
Reboot the unit and check if the fault
persists. May need to update or load
TAWS database data.
Contact ACSS Field Service before
removal.
0x00001010
TAWS Airport DB Flash Failure
Possible Cause
Airport database failure
TAWS Internal failure
Reboot the unit and check if the fault
persists. May need to update or load
airport database data.
Contact ACSS Field Service before
removal.
0x00001011
Operational SW RAM CRC Failure
Failure causes a reset
Log the fault.
0x00001012
Airport DB RAM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. May need to update or load
airport database data.
Contact ACSS Field Service before
removal.
0x00001013
Map DB RAM CRC Failure
Failure causes a reset
Log the fault.
0x00001014
TAWS Terrain Block CRC Failure
Log the fault.
0x00001015 Factory Data RAM CRC Failure
Failure causes a reset
Log the fault.
0x00001016
Config Data RAM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00001017
Factory Data NVM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00001018
Factory Data Compatibility Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00001019
Config Data NVM CRC Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x0000101A Config Data NVM Compatibility
Failure
Failure causes a reset
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x0000101B
Power Loss In Air
Check Table 4-1, Table 4-3, or Table 4-2
0x0000101C
Ambient Light Sensor Failure
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.