Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Maintenance Page 4-38
Table 4-4: List of Fault Log Messages
FAULT ID/ CODE
(HEX)
FAULT DESCRIPTION CORRECTIVE ACTION
0x00001004
DCM CRC Failure
No failures of the box only log the
fault
Reboot the unit and check if the fault
persists. Contact ACSS Field Service
before removal.
0x00001006 DCM Configuration Failure Reboot the unit and check if the fault
persists. May need to update or load
configuration data.
Contact ACSS Field Service before
removal.
0x00001007
Over Temp on Ground
Possible Cause
ADS-B In Internal failure
ADS-B Out Internal failure
TAS Internal failure
TCAS Internal failure
Transponder Internal failure
GPS Internal failure
FIS-B Internal failure
TAWS Internal failure
Log the fault and allow the unit to cool
down. If the fault continues to be seen
contact ACSS Field Service before
removal.
0x00001008
Over Temp in Air
No failures of the box only log the
fault
Log the fault and allow the unit to cool
down. If the fault continues to be seen
contact ACSS Field Service before
removal.
0x00001009
Failure of Power Monitor
Reboot the unit and check if the fault
persists. May need to update or load
configuration data.
Contact ACSS Field Service before
removal.
0x0000100A
Power Out of Tolerance
Possible Cause
ADS-B In Internal failure
ADS-B Out Internal failure
TAS Internal failure
TCAS Internal failure
Transponder Internal failure
GPS Internal failure
FIS-B Internal failure
TAWS Internal failure
Reboot the unit and check if the fault
persists. May need to update or load
configuration data.
Contact ACSS Field Service before
removal.
0x0000100B Airport DB Flash CRC Failure
Possible Cause
Airport database failure
FIS-B internal degraded
TAWS Internal failure
Reboot the unit and check if the fault
persists. May need to update or load
navigation database data.
Contact ACSS Field Service before
removal.
0x0000100C
Airport DB Flash Compatibility
Failure
Possible Cause
Airport database failure
FIS-B internal degraded
TAWS Internal failure
Reboot the unit and check if the fault
persists. May need to update or load
navigation database data.
Contact ACSS Field Service before
removal.