4.5.1 Load Software
This procedure is used to update the system software used by the unit. The MPC must be connected via
the USB connection for this procedure. The WiFi interface is not supported.
1. From the MPC (MAT) select UpdateZLoad Software. See Figure 4-7.The tool has the option of
loading either of the following software files. Note - Do not remove power to the unit or disconnect
the MPC during this procedure.
Lynx NGT-9000 Software Package File (composed of Flight and Maintenance)
GPS/UAT Composite Binary file (composed of CCA Operation SW and Firmware)
Press the Browse button to open a file window. Select the appropriate file. (i.e. 1090MSS.pkg /
GPS-UAT.bin or similar looking file). The MAT verifies the contents of the file to be loaded.
This takes approximately 5 seconds.
Press the Upload button to begin loading the software to the unit. A progress bar is shown for
each SW load.
Figure 4-7: MPC (MAT)Update Software
2. An upload completed message is shown when the procedure has finished.
A failure message is shown if a problem loading the Lynx NGT-9000 Software Package File is
detected. Check that the file being loaded is correct and try the procedure again. If the problem
continues cycle power to the unit.
A problem is detected for the GPS/UAT Composite Binary File if the validation check of the file
has failed. Check that the file being loaded is correct and try the procedure again. If the problem
continues cycle, power to the unit and try again.
When upload of Lynx NGT-9000 Software Package File is complete the unit will automatically
reset into maintenance mode. When upload of GPS/UAT Composite Binary File is complete, a
dialog will instruct the operator to cycle power on the unit.