0040-17001-01 (Revision W) Maintenance Page 4-27
Status Information provides functional status of the WX-500 at power up. This information is not updated
during operation. Use the Self Test button on the Tests screen to determine current status.
An “OK” message indicates that the WX-500 is operational and no errors are being detected.
A “Degraded” message has amber text and is followed by a “Fault Code” number and a display of
the problem.
Cycle power to the WX-500 and the NGT-9000 if a degraded message is shown. Check the startup
test again to see if the degraded message has been cleared. If not note the fault code and description.
Refer to the WX-500 Installation Manual for fault isolation information.
A “Failed” message has red text and is followed by a “Fault Code” number and a display of the
problem.
Cycle power to the WX-500 and the NGT-9000 if a failed message is shown. Check the startup test
again to see if the failed message has been cleared. If not note the fault code and description.
Refer to the WX-500 Installation Manual for fault isolation information. Errors 01 thru 15, 21, 25
thru 36, 40 thru 42 typically indicate an internal failure and that the unit needs to be sent to the
factory for repair.
4.4.5.2 Test Modes
The test modes are intended as aids in installing, testing and troubleshooting the WX-500. These test
modes are to be used only for testing and troubleshooting an installation.
The test modes provide the following options:
Noise Monitor
Test Strikes
Self Test
Test Modes are viewed on the Test Screen (see Figure 4-4). Press the Tests button (if not done already).
Individual tests are explained in the following paragraphs.
Figure 4-4: Tests Screen