Table 4-1: Troubleshooting The Panel Mount NGT-9000
SYMPTOM
SCREEN
CAUSE/CORRECTIVE ACTIONS
Display indicator Lightning
Failed (amber text) showing
on Lightning screen.
Lightning
Displayed when Lightning detection is not available.
1. Cycle power to the unit.
2. Cycle power to the WX-500.
3. Check System Status Messages.
4. Check the MPC (MAT) fault log.
5. Contact ACSS Field Service before removal of unit.
Heading shows- - -“ on
Lightning screen.
Lightning
Heading input is missing.
1. Verify STABis set to “ON(see lightning setting page)
2. Cycle power to the unit.
3. Cycle power to the WX-500.
4. Check System Status Messages.
5. Check heading source for failure.