Installation Manual

Table Of Contents
Lynx NGT-9000
Installation Manual
0040-17001-01 (Revision W) Installation Checkout Page 3-40
3.11 INSTALLATION CHECKOUT
This procedure validates the installation, calibration, and configuration setup of the Lynx NGT-9000 and
secondary equipment. Installers are advised to read the entire procedure and ensure all the necessary tool,
equipment, and data are available before performing the checkout.
Installations using the remote mount version of the NGT-9000R requires a Control Panel (RS-232 or
ARINC 429 Control Panel interface available). Depending on the installation, an approved display is also
needed for checkout. Note that approved display may not operate exactly as stated in this checkout. Refer
to the operating instructions for the display for details.
NOTE
When a procedure calls out to verify data on the Lynx NGT-9000 it is
assumed that the remote mount is verifying this same data via the display.
Consider the following prior to installation.
Perform the installation checkout procedure with aircraft on ground.
Perform only those checks that are applicable to the installation.
To conserve aircraft battery power, it is recommended that the aircraft be connected to an external
aircraft power source during installation and checkout.
An IFR-6000 (or equivalent) Ramp Test Set is required. These checks assume familiarity with the set
up and operation of the ramp test set.
All test equipment shall be calibrated in accordance with the manufacturer’s recommendations.
If the ADS-B Out Fail lamp is installed it flashes ON/OFF while the unit is starting and GPS is
initializing (acquiring signal).
Make sure that power is cycled to the unit and that the unit is in normal operation.
Be aware that foreign tail numbers may not be indicated correctly on the test equipment.
3.11.1 Functional Checks
Use the following procedure to check that the Lynx NGT-9000 (the unit) and secondary equipment is
operating properly.
3.11.1.1 WiFi Check
This check required only if the WiFi option is installed and requires a WiFi Module (i.e. WiFi dongle)
connected to the wiring harness. The PED requires a compatible APP be installed.
1. The PED, WiFi interface, and WiFi Dongle must be configured. Refer to paragraph 3.10.
2. Verify the Lynx PIM-9000 WiFi is available in the PED WiFi networks and that the PED can connect
to the Lynx WiFi signal.