0040-17001-01 (Revision W) Installation Checkout Page 3-14
3.4.1 Enable MPC to NGT-9000 Communication via USB Connection
Do the following to connect and establish communication.
1. Apply power to the unit as indicated in paragraph 3.2.1.1 (panel mount) or 3.2.2.1 (remote mount).
2. Connect USB cable between MPC and the unit.
3. From the MPC (MAT) menu, select Connect > NGT9000 > USB. See Figure 3-3.
Figure 3-3: Maintenance Application Tool Main Page Connect via USB
4. Communication is established when the MPC (MAT) left view panel changes from grey to tan and
the message "Connected" is shown in the lower communication bar. See Figure 3-4.
If "Not Connected – red indicator" is shown, then check the USB cable for proper connection.
If a "Response timeout for write request" message is seen on the status bar, then the unit is not
responding to requests. Cycle power to the unit.
When the unit is in maintenance mode the ADS-B Out Fail lamp is ON (if installed).
Panel Mount page showing
Figure 3-4: MPC (MAT) Main Screen