User's Manual
Table Of Contents
- Eclipse ODU 600 5.8 GHz ISM Band Installation Manual Rev.001
- Copyright & Terms of Use
- Aviat Networks Support
- Eclipse Product Compliance Notes
- Contents
- Volume I: Introduction and Safety
- Volume II: System Overview
- Volume III: Installation
- Chapter 1. Introduction to Installation
- Chapter 2. ODU Installation
- Chapter 3. INU and INUe Installation
- INU/INUe Overview
- Installation Requirements
- Installation Procedure
- Plug-in Installation
- INU/INUe Cable Assemblies
- DAC Trib Connectors and Cables
- NMS Connectors and Cables
- NMS 10/100Base-T Connector
- Maintenance V.24 Connector
- Auxiliary and Alarm Connectors and Cables
- AUX Data Cable: Async, HD26 to Wirewrap, 2 m
- AUX Data Cable: Sync, HD26 to Wirewrap, 2 m
- AUX Data Cable: Async, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Sync, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Async, AUX HD26 to AUX HD26, 1 m
- AUX Data Cable: Sync, AUX HD26 to AUX HD26, 1 m
- AUX Alarm I/O Cable: HD15 to Wirewrap, 2 m or 5 m
VOLUME III, CHAPTER 3, INU AND INUE INSTALLATION
l Reverse polarity protection is provided. The PCC will automatically recover
from a reverse polarity connection - the fuse will not blow. Over temperature
thermal protection is included.
l The PCC load maximum is 200 Watts. Use the power consumption data in the
preceding section to determine the maximum number of cards and ODUs that
an be supported.
l Ambient temperatures must not exceed 45
0
C (113F). The PCC should always
be installed next to the FAN card to get best air flow cooling.
l The PCC conversion efficiency is nominally 10%. To determine the power
consumed by the PCC, use a figure of 10% of the power consumed by the
INU/INUe cards and ODUs.
l When installed in an INUe the INUe must be fitted with the 2RU FAN module.
l The PCC must be connected to the NCC before applying power to the PCC to
avoid a current-inrush trip (overload) on the PCC.
l The PCC can be plugged into any INU/INUe option slot. It is not connected to
the backplane and its function is not monitored within Portal.
l Where an NPC is fitted, two PCCs are required for +24 Vdc operation, one for
the NCC, the other for the NPC. This means an INUe must be used for NCC +
NPC operation.
l If the PCC front-panel LED is not lit, it indicates the existence of abnormal
conditions such as output under-voltage, output over-voltage, loss of input
power, output over-current, or open input fuse.
Power Cables
The INU power cable is supplied in the IDC Installation Kit. It is supplied with a D-
sub M/F 2W2 connector fitted at one end and wire at the other. The cable is nom-
inally 5m (16ft), and the wires are 4mm2 (AWG12).
The cable is used for -48 Vdc connections to an NCC or NPC, or for +24 Vdc con-
nections to a PCC.
The blue wire must be connected to live (-48 Vdc or +24 Vdc); the black wire to
ground (+48 Vdc or -24 Vdc).
Figure 3-2. Power Cable and Connector
CAUTION:DC power connector can be shorted inadvertently if applied
at an angle. Always insert with correct alignment.
76 AVIAT NETWORKS