User Manual

MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 99
Object ID Group Object Type Acce
ss
Description
1.3.6.1.4.1.1316.1.1.1.2.3.6 mdrmteScStatusDump INTEGER read-
write
Allows the wayside service
(serial) channel to be used as a
diagnostics port [deprecated].
1.3.6.1.4.1.1316.1.1.1.2.4 MdrmteGeneral
1.3.6.1.4.1.1316.1.1.1.2.4.1 MdrmteStationName DisplayString read-
write
The station name is stored in the
Indoor Unit in non-volatile
memory - limited to 14
characters in length.
1.3.6.1.4.1.1316.1.1.1.2.4.2 mdrmteIUSerialNumber DisplayString read-
only
An electronic serial number is
read from the Indoor Unit - this
number is unique for each IU and
is derived from an IC that is used
within the product.
1.3.6.1.4.1.1316.1.1.1.2.4.3 mdrmteIUFirmwareVersion DisplayString read-
only
The Indoor Unit firmware version
is the version of application
firmware that loaded into the
product's application Flash.
1.3.6.1.4.1.1316.1.1.1.2.4.4 mdrmteIUBootkernelVersion DisplayString read-
only
The Indoor Unit bootkernel
version is the version of boot
firmware that loaded into the
product's Boot Flash.
1.3.6.1.4.1.1316.1.1.1.2.4.5 mdrmteOUSerialNumber INTEGER read-
only
The Outdoor Serial Number is
programmed into the OU at time
of manufacture and is read via
the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.4.6 MdrmteOUPICFirmwareVersion DisplayString read-
only
The Outdoor Unit PIC firmware
number is programmed into the
OU at time of manufacture and is
read via the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.4.7 mdrmteOUPayloadSupport INTEGER Deprecated.
1.3.6.1.4.1.1316.1.1.1.2.4.8 mdrmteDate DisplayString read-
write
This is a date record that is
recovered from the Indoor Unit's
Real Time Clock.
1.3.6.1.4.1.1316.1.1.1.2.4.9 mdrmteTime DisplayString read-
write
This is a time record that is
recovered from the Indoor Unit's
Real Time Clock.
1.3.6.1.4.1.1316.1.1.1.2.4.10 mdrmteNOVRAMInit INTEGER read-
write
If activated, the Nonvolatile
memory is initialised to a set of
default parameters.
1.3.6.1.4.1.1316.1.1.1.2.4.11 mdrmteFECBypass INTEGER read-
write
This is primarily a laboratory test
entry used to control whether the
FEC circuitry within the Indoor
Unit is activated. By default the
FEC is not bypassed i.e. FEC is
active.
1.3.6.1.4.1.1316.1.1.1.2.4.12 mdrmteFECCorrectableSymbols INTEGER read-
write
This is primarily a laboratory test
entry used to control the FEC
correction power - 20 parity
symbols are appended to the
transmit packet - 10 is the
maximum number of symbols the
FEC circuitry can correct. At a
maximum, 20 symbols in error
can be detected but only 10 can
be corrected - the higher the
correction power selected, the
greater the improvement in
system gain.
1.3.6.1.4.1.1316.1.1.1.2.4.13 mdrmteTribCode DisplayString read-
write
This is a text entry code (16
characters) used to allow
activation of tributaries on the
Indoor Units. It is unique to the
Indoor Unit based on a hardware-
dependent serial number in the
IU.
1.3.6.1.4.1.1316.1.1.1.2.4.14
mdrmteIndoorUnitBarCodeNumber
DisplayString read-
write
This is a text entry code used to
allow storage of the Indoor Unit's
bar code serial number (as seen
on the outside of the on the
outside of product's housing).