User Manual

MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 98
Object ID Group Object Type Acce
ss
Description
Indoor Units has not reactivated
within 5 seconds, the previous
(working) 'default' RF parameters
are programmed into the
respective Outdoor Units.
1.3.6.1.4.1.1316.1.1.1.2.2.9 mdrmteOURateOverride INTEGER read-
write
Deprecated
1.3.6.1.4.1.1316.1.1.1.2.2.10 mdrmteOUDataRate INTEGER read-
write
A settable rate that allows a
reduced transfer data rate over
the RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.11 mdrmteTxFrequencyCurrent INTEGER read-
only
This value [MHz] is read back
from the Outdoor Unit and
defines the transmit frequency of
the Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.12 mdrmteRxFrequencyCurrent INTEGER read-
only
This value [MHz] is read back
from the Outdoor Unit and
defines the receive frequency of
the Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.13 mdrmteNonAutoBandPlan INTEGER read-
write
Same as mdrMTEBandPlan
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the Outdoor
Unit frequencies without the “auto
recovery” feature attempting to
intervene and re-establish setup
of an operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.14 mdrmteNonAutoTxFreqPlanD INTEGER read-
write
Same as mdrTxFrequencyPlanD
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the Outdoor
Unit Plan D frequencies without
the “auto recovery” feature
attempting to intervene and re-
establish setup of an operational
RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.15 mdrmteNonAutoRxFreqPlanD INTEGER read-
write
Same as mdrTxFrequencyPlanD
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the Outdoor
Unit Plan D frequencies without
the “auto recovery” feature
attempting to intervene and re-
establish setup of an operational
RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.16 mdrmteNonAutoTxPower INTEGER read-
write
Same as mdrTxPower setting in
this MIB group except “auto
recovery” is not enabled - this
allows control of the Outdoor Unit
power level setting without the
“auto recovery” feature
attempting to intervene and re-
establish setup of an operational
RF Link.
1.3.6.1.4.1.1316.1.1.1.2.3 mdrmteServiceChannel
1.3.6.1.4.1.1316.1.1.1.2.3.1
mdrmteScDataRate
3
INTEGER read-
write
Bit rate used across the wayside
service channel link.
1.3.6.1.4.1.1316.1.1.1.2.3.2
mdrmteScDataBits
4
INTEGER read-
write
The data width - can be 7 or 8
bits.
1.3.6.1.4.1.1316.1.1.1.2.3.3 MdrmteScParity INTEGER read-
write
Serial channel - set to none, odd
or even.
1.3.6.1.4.1.1316.1.1.1.2.3.4 MdrmteScStopBits INTEGER read-
write
The number of stop bits can be
set to 1 or 2.
1.3.6.1.4.1.1316.1.1.1.2.3.5 mdrmteScFlowControl INTEGER read-
write
Either hardware or no flow control
is used.
3
Fixed at 115.2kbps in Version 1.00 and 2.00, 2.01, 2.02 IU firmware releases.
4
Serial setting 8 bits, no parity, 1 stop bit