User Manual

MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 58
The OU Station Info screen provides a brief report of the build state of the Outdoor
Unit:
Serial number loaded into the Outdoor Unit at time of manufacture.
Software version loaded into the Outdoor Unit at time of manufacture.
High Band Transmitter affects the way the channel plan is implemented on the
Outdoor Unit.
Low Band Transmitter affects the way the channel plan is implemented on the
Outdoor Unit.
FCC Regulations (None, FCC, Other).
6.6.4 Outdoor Unit Status
This screen allows you to view the following Outdoor Unit status information:
Last Restart. This indicates the reason why the Outdoor Unit restarted, e.g.
Power On, Watchdog Timeout.
OU Lock Detect Status: indicates if there is a loss of lock of the IF, Transmit or
Receive path phase-locked oscillators in the OU.
6.7 RF Link Error Status Monitoring
Selected by right-clicking the relevant antenna and choosing the Diagnostics/Error option.
6.7.1 RF Link Status
Link Unavailable The RF Link is considered not available (see Link Availability definition
on next page).
Frame Unlock RF link only. It looks at data received from the link. If the link is quality
is poor, i.e. high PER at the RF level, ‘Frame Unlock’ is the result. AIS
is sent from the transceiver (from link direction) as long as ‘Frame
Unlock’ is true and no reliable data is available.
Packet Error Rate
Fault
The PER Monitoring has been enabled and the Instantaneous PER has
exceeded the configured PER Fault Threshold for the RF link.
ESR Exceeded RF Errored Second Ratio has been exceeded due to Packet errors on
the RF link.
SESR Exceeded RF Seriously Errored Second Ratio has been exceeded due to Packet
errors on the RF link.
BBER Exceeded RF Background Block/Packet Errors Ratio has been exceeded due to
block errors on the RF link.