User Manual

MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 52
Link Unavailable
Frame Unlock
Minor PER Exceeded
RF Link
ESR Exceeded
LOS Payload Interface
AIS
Use the Apply Changes button to change settings.
Use the Exit button to exit without any changes being made.
6.5.1.5 Indoor Unit Loopback Controls
These controls allow you to set the loopbacks on the payload data.
IU Loopback to Line - Used to loopback the data on the payload interface so
that incoming user payload data is sent straight back to the user. The payload
data does not go out over the RF link.
IU Loopback to RF Link - Used to loopback the payload (Indoor Unit)/Outdoor
Unit data so that payload data arriving over the RF link is looped and sent back
across the RF link.
Perform a loopback as follows:
1. Select the Loopback Type by choice of arrows on the IU being tested.
2. Select the Loopback Timeout Time (in seconds). If enabled, the Loopback
state will cancel after Time seconds and the unit will return to normal operation.
3. Click on the Loopback Timeout Enable checkbox.
4. Click on the Apply Changes button.
6.5.2 Menu Items
6.5.2.1 Date/Time Entry
In his menu, the user has the option of entering the:
Date (change date using the calendar display)
Time (change time using the spin button on the right-hand side of the control or enter
manually).
The user had the option of ‘fetching’ the date and time from the PC or Laptop and using this
information.
Use the Apply Changes button once the update in the Indoor Unit is to be made.
6.5.2.2 Station Status