User Manual

MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 31
4.2.5 Unbalanced Payload Data
For a later variant of the Indoor Unit, there is a set of 75 Ohm BNC’s on the front panel.
Rx implies IN (signal expected to go INTO the interface)
Tx implies OUT (signal coming OUT of the interface)
4.2.6 Connecting Auxiliary In/Out (Optional)
The auxiliary in/out port is used to:
Monitor switch-closure events using two isolated inputs.
Control line connections using normally-open and normally-closed relay outputs.
Connect the port:
1. Assemble an auxiliary in/out cable using a 15 way D-type male connector
according to connector pin assignments shown in Table 7.
2. Connect to the cable Indoor Unit auxiliary in/out connector.
3. Secure the connector using locking screws.
Table 7. Auxiliary In/Out Connector Pin Outs
Indoor unit connector Pin
No
Signal
1 OUTPUT 1 COMMON
2 OUTPUT 1 NORMALLY-OPEN
3 OUTPUT 1 NORMALLY-OPEN
4 OUTPUT 1 NORMALLY-CLOSED
5 OUTPUT 1 NORMALLY-CLOSED
6 OUTPUT 1 COMMON
7 OUTPUT 2 COMMON
8 OUTPUT 2 COMMON
9 OUTPUT 2 NORMALLY-OPEN
10 OUTPUT 2 NORMALLY-OPEN
11 OUTPUT 2 NORMALLY-CLOSED
12 INPUT 1
13 INPUT 1 RETURN
14 INPUT 2
15-pin D-type female
1
8
9
15
15 INPUT 2 RETURN