2.3 Indoor Unit
The Indoor Unit is designed for mounting in a 19” rack, occupying a 1U slot, or can be
table-top standing.
The Indoor Unit accepts user nE1/nT1 and combines it with Wayside Service Serial
Data and IP data to be transmitted across the radio link.
The Indoor Unit is fitted with a DC power supply.
A firmware variant exists that determines whether the Outdoor Unit is an MDR2400 or
MDR5800. The Indoor Unit hardware is independent of the type of Outdoor Unit i.e.
whether it is an MDR2400 or MDR5800.
2.3.1 Payload Interface Options
The Indoor Unit can be configured for nE1 or nT1 operation.
1, 2 or 4 x E1 (2.048 Mbps)
1, 2 or 4 x E1 (1.544 Mbps)
For E1 connectivity, bipolar AMI or HDB3 line coding is software selectable.
For T1 connectivity, bipolar AMI or B8ZS line coding is software selectable.
MDR MTE 75/120 OHM INDOOR UNIT 651-04008-02
MDR MTE INDOOR UNIT V2 651-03810-02