User Manual
MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 113
13 APPENDIX E: MDR5800 FIXED ANTENNAS
The table below identifies the distances where the 1mW/cm
2
exposure limits may be
exceeded during continuous transmission using the proposed fixed antennas.
Manufacturer Type Model Gain
(dBi)
Numeric
gain
Channel Peak
Power
(mW)
Calculated
Distance (m)
Minimum RF
Exposure
Separation
Distance (m)
Gabriel Dish SSSP2 52B 29.0 794.3 3 239.9 1.2 2
Gabriel Flat panel DFPD1-52 23.9 245.5 3 239.9 0.7 2
MTI Flat panel MT-20004 28.0 631.0 3 239.9 1.1 2
WARNING: It is the responsibility of the professional installer to ensure that when using the
outdoor antenna kits in the United States (or where FCC rules apply), only these antenna
configurations shown in the table above are used. The use of any antenna other than those listed
is expressly forbidden in accordance to FCC rules CFR47 part 15.204.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment when installed as directed. This equipment should be installed and operated with fix-
mounted antennas that are installed with a minimum of 2 meters of separation distance between
the antenna and all persons body during normal operation and the antennas as shown above.