User Manual
MDR2400 and MDR5800 User Manual
862-01881 Issue 8 Page 100
Object ID Group Object Type Acce
ss
Description
1.3.6.1.4.1.1316.1.1.1.2.4.15
mdrmteIndoorUnitPCBrevision†
DisplayString read-
write
"This is a numeric entry code
used to reflect the PCB revision
number and modification status."
1.3.6.1.4.1.1316.1.1.1.2.5 mdrmteFirmware
1.3.6.1.4.1.1316.1.1.1.2.5.1
mdrmteFTPServerStatus†
INTEGER read-
write
This allows
activation/deactivation of the FTP
server that runs in the Indoor Unit
and is used to upload new
revisions of firmware via a routed
IP network.
1.3.6.1.4.1.1316.1.1.1.2.5.2
mdrmteFlashNewFirmware†
INTEGER read-
write
This entry determines the time
when the new version of firmware
will be activated.
1.3.6.1.4.1.1316.1.1.1.3 mdrmteFault
1.3.6.1.4.1.1316.1.1.1.3.1 mdrmteInfo
1.3.6.1.4.1.1316.1.1.1.3.1.1 mdrmteLEDTable SEQUENCE A group of LEDs on the front
panel of the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1 mdrmteLEDEntry SYNTAX A LED entry containing objects
describing a particular LED.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.1 mdrmteLEDIndex INTEGER A unique value for each LED in
the Indoor Unit. Its value ranges
from 1 to the number of LEDs on
the front panel of the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.2 mdrmteLEDLabel DisplayString read-
only
SYSTEM Green OK, Orange
(OU/IU Comms Error), Red
(OU/IU Comms Down)
PAYLOAD Green OK, Orange
(AIS Detected), Red (LOS
Detected)RF LINK Green OK,
Orange (FEC Correcting Errors),
Red (FEC unable to correct
errors)In ALL cases flashing red
and orange LEDs imply historic
alarm conditions (The alarm can
be cleared using the front panel
button 'position 1': see next
paragraph).
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.3 mdrmteLEDState INTEGER read-
only
The current state of the LED - for
a detailed description of
functionality, see the
mdrmteLEDLabel entry.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.4 mdrmteLEDColour INTEGER read-
only
The current colour of the LED -
for a detailed description of
functionality, see the
mdrmteLEDLabel entry.
1.3.6.1.4.1.1316.1.1.1.3.1.2 mdrmteOutdoorUnitComms INTEGER read-
only
Describes the state of
communication with the Outdoor
unit in terms of whether it is up or
down completely. Alternatively, if
there were errors, these are
identified as comms errors
(based on a CRC check) or
content errors (i.e. undeclared,
unused messages).
1.3.6.1.4.1.1316.1.1.1.3.1.3 mdrmteOutdoorUnitResetType INTEGER read-
only
This message is read from the
Outdoor Unit and identifies the
last reason for a reset within the
OU.
1.3.6.1.4.1.1316.1.1.1.3.1.4 mdrmteOutdoorUnitLockDetect INTEGER read-
only
The transmit RF synthesizer,
receive RF synthesizer and IF
phased locked loop lock detect
signals are monitored and
reported via this MIB element.
1.3.6.1.4.1.1316.1.1.1.3.2 mdrmteSelfTest
1.3.6.1.4.1.1316.1.1.1.3.2.1 mdrmteFlash INTEGER read-
only
Identifies pass/fail status of the
Indoor Unit's application flash.
1.3.6.1.4.1.1316.1.1.1.3.2.2 mdrmteDRAM INTEGER read-
only
Identifies pass/fail status of the
Indoor Unit's Dynamic RAM.