User's Manual
Table Of Contents
- Eclipse Installation Manual for 5.8 GHz Unlicensed Band Rev.003
- Copyright & Terms of Use
- Aviat Networks Support
- Eclipse Product Compliance Notes
- Contents
- Volume I: Introduction and Safety
- Volume II: System Overview
- Volume III: Installation
- Chapter 1. Introduction to Eclipse Installation
- Chapter 2. IRU 600 Installation
- Chapter 3. INU and INUe Installation
- INU/INUe Overview
- Installation Requirements
- Installation Procedure
- Plug-in Installation
- INU/INUe Cable Assemblies
- DAC Trib Connectors and Cables
- NMS Connectors and Cables
- NMS 10/100Base-T Connector
- Maintenance V.24 Connector
- Auxiliary and Alarm Connectors and Cables
- AUX Data Cable: Async, HD26 to Wirewrap, 2 m
- AUX Data Cable: Sync, HD26 to Wirewrap, 2 m
- AUX Data Cable: Async, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Sync, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Async, AUX HD26 to AUX HD26, 1 m
- AUX Data Cable: Sync, AUX HD26 to AUX HD26, 1 m
- AUX Alarm I/O Cable: HD15 to Wirewrap, 2 m or 5 m
ECLIPSE INSTALLATION MANUAL
Elevated ambi ent temperatures should be avoided. The
ambient temperature is the air temperature in the immediate
operati ng environment of the chassis, which if installed in a
rack, is the ambient applying to its location withi n the rack.
CAUTION:The ambient temperature maximums must not be
exceeded. Over-temperature operation is a primary factor affecting
long term component reliability.
PCC +24 Vdc Operation
The PCC is for use with standard +24 Vdc (-ve grounded) battery-backed power
supply systems.
l One PCC supports a maximum three IRU 600v1 or v2 RFUs, plus any
combination of RACs and DACs.
l One PCC supports a maximum two IRU 600v3 RFUs, plus any combination of
RACs and DACs.
l The PCC +ve and -ve input terminals are isolated from chassis (ground). The -
ve input is grounded by the -ve grounded power supply connection.
l The PCC 20A fuse is fitted in the +ve input. It is a PCB mount type and is not
field replaceable.
l Reverse polarity protection is provided. The PCC will automatically recover
from a reverse polarity connection - the fuse will not blow. Over temperature
thermal protection is included.
l The PCC load maximum is 200 Watts. Use the power consumption data in the
preceding section to determine the maximum number of cards and RFUs that
an be supported.
l Ambient temperatures must not exceed 45
0
C (113F). The PCC should always
be installed next to the FAN card to get best air flow cooling.
l The PCC conversion efficiency is nominally 10%. To determine the power
consumed by the PCC, use a figure of 10% of the power consumed by the
INU/INUe cards and RFUs.
l When installed in an INUe the INUe must be fitted with the 2RU FAN module
as it provides almost double the air flow of the 1RU FAN modules.
l The PCC must be connected to the NCC before applying power to the PCC to
avoid a current-inrush trip (overload) on the PCC.
l The PCC can be plugged into any INU/INUe option slot. It is not connected to
the backplane and its function is not monitored within Portal.
l Where an NPC is fitted, two PCCs are required for +24 Vdc operation, one for
the NCC, the other for the NPC. This means an INUe must be used for NCC +
NPC operation.
l If the PCC front-panel LED is not lit, it indicates the existence of abnormal
conditions such as output under-voltage, output over-voltage, loss of input
power, output over-current, or open input fuse.
260-668066-001 OCTOBER 2012 65