Elevated ambi ent temperatures should be avoided. The
ambient temperature is the air temperature in the immediate
operati ng environment of the chassis, which if installed in a
rack, is the ambient applying to its location withi n the rack.
CAUTION:The ambient temperature maximums must not be
exceeded. Over-temperature operation is a primary factor affecting
long term component reliability.
PCC +24 Vdc Operation
The PCC is for use with standard +24 Vdc (-ve grounded) battery-backed power
supply systems.
l One PCC supports a maximum three IRU 600v1 or v2 RFUs, plus any
combination of RACs and DACs.
l One PCC supports a maximum two IRU 600v3 RFUs, plus any combination of
RACs and DACs.
l The PCC +ve and -ve input terminals are isolated from chassis (ground). The -
ve input is grounded by the -ve grounded power supply connection.
l The PCC 20A fuse is fitted in the +ve input. It is a PCB mount type and is not
field replaceable.
l Reverse polarity protection is provided. The PCC will automatically recover
from a reverse polarity connection - the fuse will not blow. Over temperature
thermal protection is included.
l The PCC load maximum is 200 Watts. Use the power consumption data in the
preceding section to determine the maximum number of cards and RFUs that
an be supported.
l Ambient temperatures must not exceed 45
0
C (113F). The PCC should always
be installed next to the FAN card to get best air flow cooling.
l The PCC conversion efficiency is nominally 10%. To determine the power
consumed by the PCC, use a figure of 10% of the power consumed by the
INU/INUe cards and RFUs.
l When installed in an INUe the INUe must be fitted with the 2RU FAN module
as it provides almost double the air flow of the 1RU FAN modules.
l The PCC must be connected to the NCC before applying power to the PCC to
avoid a current-inrush trip (overload) on the PCC.
l The PCC can be plugged into any INU/INUe option slot. It is not connected to
the backplane and its function is not monitored within Portal.
l Where an NPC is fitted, two PCCs are required for +24 Vdc operation, one for
the NCC, the other for the NPC. This means an INUe must be used for NCC +
NPC operation.
l If the PCC front-panel LED is not lit, it indicates the existence of abnormal
conditions such as output under-voltage, output over-voltage, loss of input
power, output over-current, or open input fuse.
260-668066-001 OCTOBER 2012 65