User's Manual
Table Of Contents
- Eclipse Installation Manual for 5.8 GHz Unlicensed Band Rev.003
- Copyright & Terms of Use
- Aviat Networks Support
- Eclipse Product Compliance Notes
- Contents
- Volume I: Introduction and Safety
- Volume II: System Overview
- Volume III: Installation
- Chapter 1. Introduction to Eclipse Installation
- Chapter 2. IRU 600 Installation
- Chapter 3. INU and INUe Installation
- INU/INUe Overview
- Installation Requirements
- Installation Procedure
- Plug-in Installation
- INU/INUe Cable Assemblies
- DAC Trib Connectors and Cables
- NMS Connectors and Cables
- NMS 10/100Base-T Connector
- Maintenance V.24 Connector
- Auxiliary and Alarm Connectors and Cables
- AUX Data Cable: Async, HD26 to Wirewrap, 2 m
- AUX Data Cable: Sync, HD26 to Wirewrap, 2 m
- AUX Data Cable: Async, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Sync, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Async, AUX HD26 to AUX HD26, 1 m
- AUX Data Cable: Sync, AUX HD26 to AUX HD26, 1 m
- AUX Alarm I/O Cable: HD15 to Wirewrap, 2 m or 5 m
VOLUME III, CHAPTER 2, IRU 600 INSTALLATION
Figure 2-4. IRU 600v2 Tx Switch and RFUv2 Connections
Figure 2-5. IRU 600v3 Tx Switch and RFUv3 Connections
CAUTION:Ambient temperatures must not exceed 55
0
C (131
0
F). If
installed in a rack cabinet, it is the ambient within the cabinet.
Grounding
The chassis grounding stud accommodates ground cables up to 16 mm
2
(AWG 6).
The stud also provides jack plug connection for a wrist strap.
1. Ground the IRU 600 from the grounding stud to the rack/frame ground bar
using 4 mm
2
(AWG 12) green PVC insulated stranded copper wire with a
suitably sized crimp lug at the ground bar end (supplied by the installer).
For NEBS grounding compliance, see below.
2. If the equipment rack/frame requires grounding, use 16 mm
2
(AWG 6) wire
from its ground bar to the station ground.
52 AVIAT NETWORKS