User's Manual

260-668066-003 Rev 001 August 2010 6-7
Eclipse Installation Manual
FAN module removal and replacement does not affect INUe traffic.
2. Fasten in place using the screw supplied. Do not over-tighten - the screw is
designed to bite into the unthreaded hole provided in the plastic frame.
3. Replace the FAN module.
Installation instructions are included with the fan filter kit.
Figure 6-5. Location of Fan Air Filter in INUe
Power Line Filter Option
An external DC power line filter option is available and must be installed with an INU/
INUe for NEBS compliance. It ensures Eclipse meets EMI requirements specified
within Telcordia GR-1089-CORE, Issue 4, June 2006.
It is 1RU tall and 140mm wide (5.5”), and is supplied as a kitset comprising the filter
unit, bracket for left or right side rack mounting, and a short 2W2-to-2W2 cable for
connecting the filter unit to the NCC or NPC -48 Vdc inputs.
Where an NPC is fitted, two filter units are required, one for the NCC, the other for
the NPC.
The standard power cable supplied with an INU or NPC is re-used as the power input
cable for the filter unit.
Figure 6-6. Power Line Filter with Bracket