User Manual

MDR2400/5800-SR, Orion2410/5810-SRi and Orion 5825-SR
862-01881 Issue 12c Page 126
Figure 13:
Orion Protection Kit front panel.
Figure 14:
Tributary channel interface cable used to connect Protection Kit Paths A & B
to the two Digital Indoor Units.
DIU auxiliary communications cables are supplied with the Protection Kit and are used
to connect the auxiliary ports of the two Digital Indoor Units according to Table 15.
The system diagram when using the two radio pairs in bridging mode is shown in
Figure 10
.
Table 15:
Auxiliary Port cross connection.
J.4.2 Radio Software Configuration
Two MIB elements are used to configure the radios taking part in the protected radio
link. These MIB elements can be set using any SNMP element manager application,
or through the Orion NMS application. Please refer to the following user manuals for
details on using the above applications:
MDR / Orion – SR user manual
Orion NMS HTML user manual
3
rd
party user manual (If a 3
rd
party SNMP element manager / MIB browser is
used.
Set the following MIB element in all IDUs taking part in the protected radio link to 1
(Yes). mdrmteOnePlusOne (OID: 1.3.6.1.4.1.1316.1.1.1.2.4.17, Parent:
mdrmteGeneral)
Radio 1A Pin No Radio 1B Pin No
1 12
2 13
8 14
9 15
12 1
13 2
14 8
15 9