User Manual
MDR2400/5800-SR, Orion2410/5810-SRi and Orion 5825-SR
862-01881 Issue 12c Page 117
I Appendix: Getting started guide
I.1 Checklist for Bench Testing (without a PC)
You will need the following: Chec
k
Additional Information
1 1 MDR / Orion User Manual
(Issue 11)
2 2 Digital Indoor Units
3 2 RF Units 1 low and 1 high band - see L/H
stamp near serial number
4 1 or 2 Power supplies User Manual par. 4.2.3 and 8.4
5 2 Digital Indoor Unit power
cables
User Manual par. 4.2.3
6 2 Indoor to RF Unit power
cables
Specifications - User Manual par.
8.5.10
7 2 Indoor to Outdoor RJ45 Data
cables
Connections - User Manual par.
4.4.1
8 N-type male to N-type male (6
GHz) RF cable
Type and connection - User
Manual par. 4.3.1
9 60 - 90 dB of N-type attenuators Note Max input is -30 dBm, default
output power is +24 dBm
10 2.5 mm Allen Key Required to open the connector lid
on the RF Unit.
11 3 mm terminal screwdriver Required to connect the power
cables
Recommended items:
12 T1 or E1 BER Tester
13 T1/E1 Payload cable User Manual par. 4.2.4, 4.2.5,
4.2.6
14 Payload Loopback Connector User Manual par. 4.2.4, 4.2.5,
4.2.6
You will need to know:
15
How to use the reset button:
When you press and hold down the reset button on the front panel with a suitable
tool,the 3 LEDs on the front panel will change state depending on the duration that
the button is held down for:
Count the number of state changes and let go of the reset button when the desired
count is reached: It starts off with one green LED in the right most position,
"moving" to the left:
Numb
er
Left
(System)
Middle(Payloa
d)
Right (RF
Link)
1 off off Green