User Manual

MDR2400/5800-SR, Orion2410/5810-SRi and Orion 5825-SR
862-01881 Issue 12c Page 105
39 mdrmteTrapOUEepromWrite : Minor Indicates there was an attempt to write to the RF Unit EEPROM.
40 MdrmteTrapOUSetTxPower : Informational Indicates there was an attempt to change the transmit power.
41 MdrmteTrapOUSetPNCode Deprecated
42 MdrmteTrapOUSetAutoRecovery Indicates there was an attempt to change the 'auto recovery' setting.
43 MdrmteTrapOUProgramConfig Deprecated
44 mdrmteTrapOUChangeRFLoopback : Informational Indicates a change the RFU RF Loopback setting was implemented.
45 mdrmteTrapOUChangeBBPLoopback : Informational Indicates a change the Baseband Processor Loopback setting was
implemented.
46 mdrmteTrapOUWriteBBP : Minor Indicates there was an attempt to write to the Baseband Processor.
47 mdrmteTrapSetDate : Informational Indicates the Digital Indoor Unit date was adjusted.
48 mdrmteTrapSetTime : Informational Indicates the Digital Indoor Unit time was adjusted.
49 mdrmteTrapSynchronizeSwRTC : Informational Indicates the Digital Indoor Unit's time was synchronized with its real-
time clock.
50 MdrmteTrapSetRelayLabel A relay label was changed.
51 MdrmteTrapSetRelayOpenStateLabel A relay open-state label was changed.
52 MdrmteTrapSetRelayClosedStateLabel A relay closed-state label was changed.
53 mdrmteTrapSetRelayDefaultState : NA Deprecated
54 mdrmteTrapSetRelayCurrentState : Informational Relay's current state has changed
55 MdrmteTrapRelayScriptEnable Relay scripting is enabled.
56 MdrmteTrapRelayScriptDisable Relay scripting is disabled.
57 mdrmteTrapGetEventLog : Informational Digital Indoor Unit's event log is being accessed.
58 mdrmteTrapClearEventLog : Informational Digital Indoor Unit's event log is being cleared.
59 mdrmteTrapSelfTestFailure : Major Digital Indoor Unit's self test failed.
60 mdrmteTrapProcessorReset : Critical There was an Digital Indoor Unit processor reset.
61 MdrmteTrapEtherRx There was an Digital Indoor Unit Receive Ethernet buffer error.
62 mdrmteTrapTest : Informational Test trap
63 MdrmteTrapGenericText Test trap
64 mdrmteTrapGenericText_Data Test trap
65 mdrmteTrapGenericText_DecData Test trap
66 mdrmteTrapSocket_Error Test trap
67 mdrmteLog_Link_Status : Informational The Event Log was cleared, so a summary of the status has been
logged.
68 mdrmteLog_Link_Errors : Informational One or more packet errors occurred in the last error window.
69 mdrmteLog_Link_Corrections : Informational One or more corrected symbols occurred in the last error window.
70 mdrmteLocRelayScriptOpen : Minor A relay opened as a result of a local relay scripting event.
71 mdrmteLocRelayScriptClose : Minor A relay closed as a result of a local relay scripting event.
72 mdrmteRemRelayScriptOpen : Minor A relay opened as a result of a remote relay scripting event.
73 MdrmteRemRelayScriptClose : Minor A relay closed as a result of a remote relay scripting event.
74 mdrmteRemScriptEvent : Minor A remote event occurred which will be processed by relay scripting.
75 MdrmteTrapLinkFrameUnlockAgain Indicates a Frame Unlock condition associated with the Digital Indoor
Unit
76 MdrmteTrapOUSetFrequencies Indicates the RF Unit receive frequencies were changed.
77 MdrmteTrapOUSetPersonality Indicates the RF Unit FPGA personality was changed.