Object ID Object name Object Type
Access
Rights
Description
.1316.1.1.1.2.2.15 mdrmteNonAutoRxFreqPlanD INTEGER read-write
Same as
mdrRxFrequencyPlanD
setting in this MIB group
except autorecovery is not
enabled - this allows
control of the Outdoor
.1316.1.1.1.2.2.16 mdrmteNonAutoTxPower INTEGER read-write
Same as mdrTxPower
setting in this MIB group
except autorecovery is not
enabled - this allows
control of the Outdoor
.1316.1.1.1.2.2.17 mdrmteRadioType INTEGER read-only
This value is read from the
RF Unit via the Digital
Indoor Unit and defines
.1316.1.1.1.2.2.18 mdrmteSevereErrorMargin INTEGER read-write
Defines the percentage
threshold (1-99) used
when calculating in a one
second period
.1316.1.1.1.2.2.19 mdrmteTimedMute INTEGER write-only
Initiates muting of
transmitted signal for a
short period to facilitate
spectral analysis.
.1316.1.1.1.2.3 mdrmteServiceChannel
.1316.1.1.1.2.3.1 mdrmteScDataRate INTEGER read-write
Bit rate used across the
wayside service channel
link
.1316.1.1.1.2.3.2 mdrmteScDataBits INTEGER read-write
The data width - can be 7
or 8 bits
.1316.1.1.1.2.3.3 mdrmteScParity INTEGER read-write
Serial channel - set to
none, odd or even
.1316.1.1.1.2.3.4 mdrmteScStopBits INTEGER read-write
The nuber of stop bits can
be set to 1 or 2
.1316.1.1.1.2.3.5 mdrmteScFlowControl INTEGER read-write
Either hardware or no flow
control is used
.1316.1.1.1.2.3.6 mdrmteScStatusDump INTEGER read-write
Allows the wayside service
(serial) channel to be used
as a diagnostics port
.1316.1.1.1.2.4 mdrmteGeneral
.1316.1.1.1.2.4.1 mdrmteStationName DisplayString read-write
The station name is stored
in the Digital Indoor Unit in
nonvolatile memory
.1316.1.1.1.2.4.2 mdrmteIUSerialNumber DisplayString read-only
An electronic serial
number is read from the
Digital Indoor Unit - this
number is unique
.1316.1.1.1.2.4.3 mdrmteIUFirmwareVersion DisplayString read-only
The Digital Indoor Unit
firmware number is the
version of application
firmware that is loaded
into
.1316.1.1.1.2.4.4 mdrmteIUBootkernelVersion DisplayString read-only
The Digital Indoor Unit
bootkernel version is the
version of boot firmware
that is loaded into
.1316.1.1.1.2.4.5 mdrmteOUBarCode INTEGER read-only
The RF Unit bar-code
number is programmed
into the RFU at time of
manufacture and is read
via the
.1316.1.1.1.2.4.6 mdrmteOUPICFirmwareVersion DisplayString read-only
The RF Unit PIC firmware
number is programmed
into the RFU at time of
manufactute and is read
via the
.1316.1.1.1.2.4.7 mdrmteOUPayloadSupport INTEGER read-only Deprecated
.1316.1.1.1.2.4.8 mdrmteDate DisplayString read-write
This is a date record that
is recovered from the
Digital Indoor Unit's Real
Time Clock