User Manual

MDR2400/5800-SR, Orion2410/5810-SRi and Orion 5825-SR
862-01881 Issue 12c Page 89
B.2 The MIB Elements – OID (Object ID) DESCRIPTIONS
Object ID Object name Object Type
Access
Rights
Description
.1316 plessey
.1316.1 products
.1316.1.1 digitalradio
.1316.1.1.1 mdrmte
.1316.1.1.1.1 mdrmtePerformance
.1316.1.1.1.2 mdrmteConfiguration
.1316.1.1.1.3 mdrmteFault
.1316.1.1.1.4 mdrmteAccess
.1316.1.1.1.5 mdrmteRelayOutputs
.1316.1.1.1.6 mdrmteOptoInputs
.1316.1.1.1.1.1 mdrmtePayloadPerf
.1316.1.1.1.1.1.1 mdrmtePpTable SEQUENCE not-accessible
.1316.1.1.1.1.1.1.1 mdrmtePpEntry MdrmtePpEntry not-accessible
.1316.1.1.1.1.1.1.1.1 mdrmtePpIndex INTEGER read-only
.1316.1.1.1.1.1.1.1.2 mdrmtePpLOS INTEGER read-only
A Loss of Signal has been
detected on the input to a
tributary - there is one for
each tributary (0, 1, 2, 3,
...)
.1316.1.1.1.1.1.1.1.3 mdrmtePpAIS INTEGER read-only
An Alarm Indication Signal
has been detected on the
input to a tributary - there
is one for each tributary (0,
1, 2, 3, ...)
.1316.1.1.1.1.1.2 mdrmteCrcErrors INTEGER read-only
The number of CRC4 or
CRC6 errors seen on the
selected tributary since the
last time errors were
cleared.
.1316.1.1.1.1.1.3 mdrmteCrcTribSelect INTEGER read-write
The tributary selected for
CRC checking.
.1316.1.1.1.1.1.4 mdrmteCrcLock INTEGER read-only
Indication of whether the
CRC checking algorithm
has locked onto a CRC
frame signature in the
payload data.
.1316.1.1.1.1.1.5 mdrmteCrcEbitCnt INTEGER read-only
Reflects the number of
assertions of the 'E' bits in
selected tributary.
.1316.1.1.1.1.2 mdrmteRFLinkPerf
.1316.1.1.1.1.2.1 mdrmteCarrierDetect INTEGER read-only
Indicates if a RF Carrier
has been detected by the
RF Unit - if so, the header
in the RF Packet has been
identified as a potential
valid packet - note
however, that it could be
received from another
transmitter that uses the
same header format
.1316.1.1.1.1.2.2 mdrmteRSSI Gauge read-only
A dBm value
representative of the
received signal level. The
value detected is
representative of the level
that would be measured
should a spread spectrum
signal be input at the RF
Unit's Diplexer RF Port - a
CW (Continuous Wave)
signal will appear to be 20
dB higher