8 Technical Data
8.1 Environmental Requirements
8.1.1 Outdoor Equipment
Operating temperature: -30°C to +60°C
Relative humidity: 8-100%
Atmospheric pressure: 0.7 to 1.06 kPa
Lightning protection ITU-T K.20
8.1.2 Indoor Equipment
Operating temperature: 0°C to +50°C
Relative humidity: 5-90%
Lightning protection: ITU-T K.20
8.2 Mechanical Information for Outdoor Equipment
Dimensions (HxWxD):
335mm x 231mm x 124mm
Weight:
~ 5.9 Kg
8.3 Mechanical Information for Indoor Equipment
Dimensions (HxWxD): 45mm x 480 mm x 265mm
Mounting: 19” Rack, 1U high or Table top
Weight: ~ 2.9 Kg
8.4 Power Supply Requirements
DC power supply: 21 to 56 VDC (58 VDC when indicated as such)
DC power supply grounding: Positively or negatively grounded
Power consumption
(MDR2400/5800)
35 W typical, 45 W maximum.
Power consumption
(Orion 5825):
35 W typical, 45 W maximum – standard power
42 W typical, 52 W maximum – high power