User's Manual

MDR2400-SR, MDR5800-SR and Orion 5825-SR
Issue 10 Page 105
40 MdrmteTrapOUSetTxPower : Informational Indicates there was an attempt to change the transmit power.
41 MdrmteTrapOUSetPNCode Deprecated
42 MdrmteTrapOUSetAutoRecovery Indicates there was an attempt to change the 'auto recovery' setting.
43 MdrmteTrapOUProgramConfig Deprecated
44 mdrmteTrapOUChangeRFLoopback : Informational Indicates a change the OU RF Loopback setting was implemented.
45 mdrmteTrapOUChangeBBPLoopback : Informational Indicates a change the Baseband Processor Loopback setting was
implemented.
46 mdrmteTrapOUWriteBBP : Minor Indicates there was an attempt to write to the Baseband Processor.
47 mdrmteTrapSetDate : Informational Indicates the Indoor Unit date was adjusted.
48 mdrmteTrapSetTime : Informational Indicates the Indoor Unit time was adjusted.
49 mdrmteTrapSynchronizeSwRTC : Informational Indicates the Indoor Unit's time was synchronized with its real-time
clock.
50 MdrmteTrapSetRelayLabel A relay label was changed.
51 MdrmteTrapSetRelayOpenStateLabel A relay open-state label was changed.
52 MdrmteTrapSetRelayClosedStateLabel A relay closed-state label was changed.
53 mdrmteTrapSetRelayDefaultState : NA Deprecated
54 mdrmteTrapSetRelayCurrentState : Informational Relay's current state has changed
55 MdrmteTrapRelayScriptEnable Relay scripting is enabled.
56 MdrmteTrapRelayScriptDisable Relay scripting is disabled.
57 mdrmteTrapGetEventLog : Informational Indoor Unit's event log is being accessed.
58 mdrmteTrapClearEventLog : Informational Indoor Unit's event log is being cleared.
59 mdrmteTrapSelfTestFailure : Major Indoor Unit's self test failed.
60 mdrmteTrapProcessorReset : Critical There was an Indoor Unit processor reset.
61 MdrmteTrapEtherRx There was an Indoor Unit Receive Ethernet buffer error.
62 mdrmteTrapTest : Informational Test trap
63 MdrmteTrapGenericText Test trap
64 mdrmteTrapGenericText_Data Test trap
65 mdrmteTrapGenericText_DecData Test trap
66 mdrmteTrapSocket_Error Test trap
67 mdrmteLog_Link_Status : Informational The Event Log was cleared, so a summary of the status has been
logged.
68 mdrmteLog_Link_Errors : Informational One or more packet errors occurred in the last error window.
69 mdrmteLog_Link_Corrections : Informational One or more corrected symbols occurred in the last error window.
70 mdrmteLocRelayScriptOpen : Minor A relay opened as a result of a local relay scripting event.
71 mdrmteLocRelayScriptClose : Minor A relay closed as a result of a local relay scripting event.
72 mdrmteRemRelayScriptOpen : Minor A relay opened as a result of a remote relay scripting event.
73 MdrmteRemRelayScriptClose : Minor A relay closed as a result of a remote relay scripting event.
74 mdrmteRemScriptEvent : Minor A remote event occurred which will be processed by relay scripting.
75 MdrmteTrapLinkFrameUnlockAgain Indicates a Frame Unlock condition associated with the Indoor Unit
76 MdrmteTrapOUSetFrequencies Indicates the Outdoor Unit receive frequencies were changed.
77 MdrmteTrapOUSetPersonality Indicates the Outdoor Unit FPGA personality was changed.