6.3.1. Station Settings Synchronization
During the synchronization of station settings:
· mandatory settings are transferred from the DataCenter to the station,
· non-mandatory settings are transferred from the Station to the DataCenter.
The synchronization is performed periodically. By default, the settings synchronization
process is done every 60 minutes. To alter the synchronization period for all stations,
follow these steps:
1. In the AVG Admin Console select Tools from the upper main menu and choose
the Shared settings for stations item.
2. Select the Remote Administration node.
3. From the Synchronize configuration every drop down menu choose the
required value. Close the dialog by clicking the OK button.
4. Wait until all stations get synchronized.
Alternatively, you can force immediate synchronization of all stations: In the
navigation tree, right-click on the Stations node and select Synchronize settings
from the context menu.
Note: To change the setting only for stations in a group, simply repeat the process
from step two after you right click on Stations/YourGroupName and select Shared
Settings for group from the context menu.
Additionally, the synchronization happens:
· every time the station powers on/goes online, its settings are synchronized at
latest within the period,
· when the station connects to the AVG DataCenter the first time, its settings
are synchronized immediately,
· when settings of a station or several stations are changed and confirmed from
the AVG Admin Console.
It is also possible to request immediate settings synchronization from the AVG Admin
Console. Simply right-click on a station's node in the navigation tree or on a particular
station in a stations view and select Synchronize settings from the context menu.