Diagnostics and Troubleshooting 10-9
229
Byte code is invalid. Byte code must be an 8-bit (1 byte) character
for Option 64. Refer to the HF (High Frequency) Application Notes for
more information.
230
Lock code is invalid. Lock code must be 0 (Unlock) or 1 (Lock) for
Option 64. Refer to the HF (High Frequency) Application Notes for
more information.
400 Invalid character following {.
403 Field separator was not found.
409
Printer memory is full. Delete unnecessary formats or graphics from
memory.
410 Parity mismatch.
411 Framing error (baud rate mismatch).
412 Flow control mismatch.
413 Online receive buffer is full. Check for a flow control problem.
611 Font, bar code, or density in the batch does not fit the format.
612
The data in this line of the batch is either missing or does not match
the format.
613 Reference point off supply.
614
Portion of field off supply or there may be an invalid character in the
packet.
703
The printer sensed a calibration of different-sized black marks. Make
sure the correct supply type is loaded.
704
Printer has not sensed a supply mark within the specified number of
inches or is out of supplies. Check the supply tracking, supply marks,
black mark sensor position, and supply roll for binding. Press
Escape/Clear and try to continue printing. Change supply.
715
Invalid data length/data mismatch. The data in the RFID Data Field
has an incorrect data length or there is a data type mismatch between
selected data type and actual data entered. This error also occurs
when there is an error in the Expanded C1Gen2 fields. Check with
your System Administrator about your format. Refer to the RFIDMP
(Multi-Protocol) Application Notes or the HF (High Frequency)
Application Notes for more information.
740
Command, hardware, inventory, or memory allocation error. There
may be an RFID hardware or memory allocation error.