Instruction manual

Common Errors
Errors 001 to 405 and 429 to 435 are data errors. This type of error
indicates that incorrect data was sent to the printer, and the printer is
ignoring it. Your System Administrator should correct the packet and send it
back to the printer.
Error
Description/Action
002 Name must be 1 to 8 characters (excluding non-printable control
characters) inside quotes.
005 Supply width is invalid.
018 Code page selection defined in the field must be 0 (Internal), 1
(ANSI), 100 (Macintosh), 101 (Wingdings), 102 (UNICODE), 103
(BIG5 for UNICODE), 104 (GB2312 for UNICODE), 105 (SJIS for
UNICODE), 106 (GB2312), 107 (BIG5), 437 (DOS Page 437),
850 (DOS Page 850), 852 (Latin 2), 855 (Russian), 857
(Turkish), 860 (Portuguese), 1250 (Latin 2), 1251 (Cyrillic), 1252
(Latin 1), 1253 (Greek), 1254 (Turkish), 1255 (Hebrew), 1256
(Arabic), 1257 (Baltic), or 1258 (Vietnamese).
025 Data length is too long.
101 Format referenced by batch not in memory.
400 Invalid character following {.
403 Field separator was not found.
409 Printer memory is full. Delete unnecessary formats or graphics
from memory.
410 Parity mismatch.
411 Framing error (baud rate mismatch).
412 Flow control mismatch.
413 Online receive buffer is full. Check for a flow control problem.
10-8 Operator's Handbook