Specifications

18 WI-125 LED Indicator User Instructions
Indicator Operation
To Activate and Control the Cutoffs
There are two ways--Methods A or B--to activate the cutoffs. Method A activates the
cutoffs immediately while displaying the changing weight on the scale, and Method B
allows you to view the weight on the scale before the cutoffs are activated.
Method A:
1. With HALtEd displayed, press MENU…
run is displayed.
2. Press SELECT…
r xxxxxx is displayed. xxxxxx represents the weight as it changes on
the scale.
Method B:
3. With HALtEd displayed, press SELECT…
h xxxxxx is displayed. xxxxxx represents the weight on the scale.
4. Press MENU…
r xxxxxx is displayed. xxxxxx represents the weight as it changes on
the scale.
To halt active cutoffs
You may halt an active cutoff at any time.
With r xxxxxx displayed, press any key…
h xxxxxx is displayed and cutoffs are halted.
To return to Gross/Net weighing mode
You may return to G/N weighing mode at any time during this process by pressing
GROSS/NET
Display returns to G/N weighing mode.
3.6 ID Number Entry
You may enter an ID number of up to 8 digits in length. The ID number may include any
combination of the numbers 0 through 9, a dash and a decimal point.
1. From gross weighing mode, press MENU repeatedly…
id. is displayed.
2. Press SELECT
The current ID number is displayed.
See Operations Menu on page 25 for menu details.