Specifications
WI-125 LED Indicator User Instructions 17
3.5 Controlling Cutoffs
3.5 Controlling Cutoffs
The WI-125 Indicator allows you to control the cutoff process from the front panel.
Through the WI-125 you may: enable/disable the cutoff process, continue or interrupt
the operation of a cutoff before its setpoint has been reached, and/or terminate the
process at any time before the last cutoff has been reached.
There are two types of cutoffs in the WI-125: the ingredient cutoff and the setpoint cutoff
(default). With ingredient cutoffs, you tell the indicator the weight of each ingredient you
want and the indicator will call for that much of each ingredient, no matter what the
weight display says. If you want 100 pounds of ingredient #1 and 100 pounds of
ingredient #2, you would enter 100 for cutoff #0 and 100 for cutoff #1.
With setpoint cutoffs, you tell the indicator at what weight display you want the cutoffs
to activate. In other words, if you want 100 pounds of ingredient #1 and 200 pounds of
ingredient #2, you would set the first setpoint cutoff at 100 and the second cutoff at 300
pounds because that is what the weight display will read when you want the actions to
occur.
You can tell which kind has been configured in your indicator by looking at the cutoff
number in the Operations menu shown below. If the cutoff number has a decimal point
following it, the cutoff is a setpoint type. If there is no decimal, it is configured as an
ingredient type.
To Access the Control Function
1. From Gross/Net Weighing Mode, press MENU one time…
Control is displayed.
2. With Control displayed, press SELECT…
HALtEd is displayed.
Some menu items may not appear in your particular situation due to configuration
setup or firmware revision level.