16 WI-125 LED Indicator User Instructions
Indicator Operation
2. Press the G/N key.
Gross weight is displayed and no tare is active.
Net Weighing Operation
1. After a tare is established, place the indicator in net mode by pressing the G/N
key.
Net annunciator illuminates. Zero weight will be displayed with the
container on the scale.
2. Place material to be weighed in the tared container on the scale.
Net weight of material is displayed.
3.4 Entering Cutoff Values Through the Front Panel
Follow the steps below to enter a cutoff value. The cutoff output will be ON below the
value entered and OFF equal to or over the value entered.
1. Push the MENU key until…
Cutoffs is displayed.
2. Push the SELECT key…
Cutoffs 0 to 7 are displayed.
3. Push the MENU key to scroll through the cutoff channels.
4. Use the numeric keypad to enter the cutoff values then press the MENU or
SELECT key.