Specifications
WI-125 LED Indicator User Instructions 15
3.3 Gross / Tare / Net Weighing Operations
Entering and/or Changing Values in Tare Registers
1. With the gross or net annunciator illuminated, press the MENU key once or
twice, depending on options enabled, until…
tArE is displayed.
2. Using the keypad, enter the number of the tare register you wish to view.
(Numbers 0-9 are allowed. For this example, tare register 5 will be used.) Key
in numeral 5.
The tare annunciator illuminates and the display shows 5 0 ,
indicating that register 5 has no value entered. (Your indicator may have
a value in register 5.)
Clearing a Tare Register
1. You can enter/change a tare value in a register in two ways:
1a. Key in a tare value: With the desired register number displayed, key in 155 for
this example, then press PRINT/SELECT.
The value 155 is accepted and tArE is displayed.
OR
1b. Use the pushbutton tare:With the desired register number displayed and the
container on the scale, press TARE.
The register number and (container weight) new tare value are
displayed.
2. Press MENU to proceed to the next tare register.
3. Press G/N to return to the weighing mode.
The value is accepted, net weight is displayed and the net annunciator
illuminates.
Clearing the Active Tare
There are two ways to remove the current or active tare weight.
1. Remove all weight from the scale and press TARE.
The current active tare register is cleared, scale returns to gross mode
and no weight is displayed.
OR
1a. With the gross or net annunciator illuminated, press MENU, then press
CLEAR.
tArE is displayed, then no tArE is displayed.
See Operations Menu on page 25 for menu details.