Specifications
WI-125 LED Indicator User Instructions 13
3.3 Gross / Tare / Net Weighing Operations
3.3 Gross / Tare / Net Weighing Operations
3.3.1 Gross Weighing
To perform gross/net weighing operations, follow these steps:
1. Power up the indicator.
Indicator powers up in gross or net mode.
2. If the unit is not in gross mode, press the G/N key once to get to gross mode.
The annunciator illuminates next to gross. See Figure 3.1.
3. Verify the scale is empty and zero the scale by pressing the ZERO key.
No weight is displayed and the zero annunciator illuminates. See Figure
3.1.
4. Select unit of measure by pressing the UNITS key.
The units annunciator will point to the chosen unit of measure.
5. Place weight on the scale.
Gross weight is displayed.
3.3.2 Net Weighing
For net weighing operations a tare needs to be entered. A tare can be entered by three
methods: using the pushbutton tare, using quick keypad tare entry, or selecting a tare
from the tare register (a memory bank of up to ten tares).
Pushbutton Tare
1. With the scale empty and the indicator powered up in gross mode, zero the
scale by pressing the ZERO key.
No weight is displayed and the zero annunciator illuminates.
2. Place the weight to be tared on the scale.
The weight of the object is displayed.
3. Press the TARE key on the indicator.
The weight is tared, the display reads zero and the net annunciator
illuminates.
You may view the current or active tare value at any time during a weighing process.
From gross or net weighing mode, press MENU, TARE is displayed, then press
SELECT. If a tare value is active, it will be displayed. If no tare value is active, NO
TARE is displayed. Press G/N to return to gross/net weighing mode. Reference the
Operations Menu section for menu details.